Multiply the published Pixel pitch of the H20T thermal sensor (12 micrometers) by the sensor resolution of 640x512 to come up with the sensor size (in millimeters).
Then taking the focal length of 13.5mm and the sensor dimensions, you use trigonometry (arctangent function) to derive the...